DC 12V/5V Digital Thermostat Temperature Control Switch Module Dual LED Multi-function Cycle Timer Relay Module Delay Time Switch

(No reviews yet) Write a Review
Gift wrapping:
Options available
Shipping:
Calculated at Checkout
$1.83
sale
Save up to
35% off

Shipping Icon Ships from JetCube >

Arrives before Christmas. Get an extra $20.00 credit if it arrives after Christmas.

Standard: FREE

Delivery: Fastest delivery in 4 business days, arrives before Christmas

Express: $12.90 or FREE (orders ≥ $35)

Delivery: Fastest delivery in 3 business days, arrives before Christmas

Commitments Icon JetCube's Commitments >

Security & Privacy
  • ✓ Safe payments
  • ✓ Secure privacy
Delivery Guarantee
  • ✓ $5.00 Credit for delay
  • ✓ 15-day no update refund
  • ✓ Return if item damaged
  • ✓ 30-day no delivery refund

Description:

Firstly: It has double LED displays, so you can set two group timing time T1 and T2. It will very convenient to customers
Secondly: There are three timing time for your choice: 0-999s 0-999min and 0-999h. You could set the timing mode as your requirement.
Thirdly: There are six operating modes for your choice.
Power: DC12V
Size: 46mm*40mm
Relay electric current: <50MA
Product Instructions
Please pay attention for your first use. You need wait 6s after your setting data, the module will save the date you have set after 6s. 
Short press button SET: If you start the time setting mode , Nixie tube will blink. You could adjust the time T1 and T2 by button+ and button-. Please wait 5s after your setting date, the module will save the date you have set after 5s 
Long press button SET: if you start the parameter setting mode. There are two group parameter for your choice  : P0 and P1. You could switch P0 or P1 by short press SET. Under the parameter P0 and P1,you could set the timing mode by the button+ and button-.
P0--0: Timing time mode : 0---999s
P0--1: Timing time mode : 0---999min
P0--2: Timing time mode : 0---999h
P1--0: The relay will connect after you delay the T1 time (Set the Mode 0 by T1)
P1--1: The relay will disconnect after you delay the T1 time (Set the Mode 1 by T1)
P1--2: The relay will connect after you delay the T1 time (Set the Mode 0 by T1) first, Then the relay will disconnect after you delay the T2 time (Set the Mode 2 by T2), it finish.
P1--3: The relay will disconnect after you delay the T1 time (Set the Mode 0 by T1) first, Then the relay will connect after you delay the T2 time (Set the Mode 2 by T2), it finish.
P1--4: The relay will connect after you delay the T1 time (Set the Mode 0 by T1) first, Then the relay will disconnect after you delay the T2 time (Set the Mode 2 by T2), it is cyclic
P1--5: The relay will disconnect after you delay the T1 time (Set the Mode 0 by T1) first, Then the relay will connect after you delay the T2 time (Set the Mode 2 by T2), it cyclic